Street Tunnel

Doors and gates in street tunnels

Flight – Rescue – Ventilation – Fire protection – Maintenance – Longevity Road tunnels are a challenging environment for doors.

The special requirements for doors in road tunnels include:

The highly corrosive climate with its mix of exhaust gases, moisture

  • Heat, road salt that has been brought in
  • Mechanical and dynamic loads from passing vehicles, especially lorries
  • Intensity of use and expected constant availability
  • Diversity of users and limited training or education opportunities- or
  • Control options; accordingly, a broad spectrum of safety and rescue scenarios

The answer to these requirements is a combination of mature products, individual engineering, high-quality materials and processing, professional assembly and efficient service. Numerous references confirm our many years of successful implementation in practice.

Nordtangente BS P1000284

Beschreibung

Einsatz
Fluchtschiebetür in Strassen- und Metrotunnels.
Als Schiebetür weniger empfindlich auf lüftungs­bedingte Druckunterschiede als eine Drehflügeltür.

Aufbau
Verschweisste Stahlblech-Verbundkonstruktion, inwendig mit Brandschutz- und Isolationsplatten ausgekleidet. Die Verstrebungen im Inneren sind den Druckbelastungen angepasst.

Öffnen / Schliessen
Die Schiebetür wird manuell geöffnet und durch ein Gegengewicht automatisch geschlossen. Die Schliess­geschwindigkeit ist pneumatisch geregelt und einstellbar.

Leistung
Feuerwiderstand : T30/EI30 nach EN1634-1 / VKF
Druck- / Sogbelastung : 2 KPa
Öffnungskraft : 100 N Erstabnahme
120 N Ereignisfall
Leckage : 0.2 3/s
Nutzungsdauer : >30 Jahre

Ausführung
Typ : einflügeliges Schiebetor
Abmessung (Standard) : 2‘971 mm x 2‘510 mm (LBxLH)
Schwellenhöhe : 0 mm bis max. 40 mm
Türblattdicke : 63 mm
Bedienung : manuell, selbstschliessend

Einsatz
Fluchtschiebetür in Strassen- und Metrotunnels.
Als Schiebetür weniger empfindlich auf lüftungs­bedingte Druckunterschiede als eine Drehflügeltür.

Aufbau
Verschweisste Stahlblech-Verbundkonstruktion, inwendig mit Brandschutz- und Isolationsplatten ausgekleidet. Die Verstrebungen im Inneren sind den Druckbelastungen angepasst.

Öffnen / Schliessen
Die Schiebetür wird manuell geöffnet und durch ein Gegengewicht automatisch geschlossen. Die Schliess­geschwindigkeit ist pneumatisch geregelt und einstellbar.

Technische Merkmale

Leistung
Feuerwiderstand : T30/EI30 nach EN1634-1 / VKF
Druck- / Sogbelastung : 2 KPa
Öffnungskraft : 100 N Erstabnahme
120 N Ereignisfall
Leckage : 0.2 3/s
Nutzungsdauer : >30 Jahre

Ausführung
Typ : einflügeliges Schiebetor
Abmessung (Standard) : 2‘971 mm x 2‘510 mm (LBxLH)
Schwellenhöhe : 0 mm bis max. 40 mm
Türblattdicke : 63 mm
Bedienung : manuell, selbstschliessend

Einsatz
Fluchtschiebetür in Strassen- und Metrotunnels.
Als Schiebetür weniger empfindlich auf lüftungs­bedingte Druckunterschiede als eine Drehflügeltür.

Aufbau
Verschweisste Stahlblech-Verbundkonstruktion, inwendig mit Brandschutz- und Isolationsplatten ausgekleidet. Die Verstrebungen im Inneren sind den Druckbelastungen angepasst.

Öffnen / Schliessen
Die Schiebetür wird manuell geöffnet und durch ein Gegengewicht automatisch geschlossen. Die Schliess­geschwindigkeit ist pneumatisch geregelt und einstellbar.

Leistung
Feuerwiderstand : T30/EI30 nach EN1634-1 / VKF
Druck- / Sogbelastung : 2 KPa
Öffnungskraft : 100 N Erstabnahme
120 N Ereignisfall
Leckage : 0.2 3/s
Nutzungsdauer : >30 Jahre

Ausführung
Typ : einflügeliges Schiebetor
Abmessung (Standard) : 2‘971 mm x 2‘510 mm (LBxLH)
Schwellenhöhe : 0 mm bis max. 40 mm
Türblattdicke : 63 mm
Bedienung : manuell, selbstschliessend

 

Swinging doors

From the standard door in the service room to the escape door in the crossover passage

As a door and frame specialist, Elkuch has developed a wide range of doors over the years to meet the diverse applications found in tunnel construction. If required, an equally individual solution can also be found for individual tasks.

  • Opening: one or two-leaf
  • Manual, with opening aid or with drive
  • Fire resistance: none, EI30, EI60, EI90, EI120
  • Pressure load up to 5 kPa
  • Break-in resistance up to RC3
  • Steel or stainless steel according to specification, also with powder coating
  • Dimensions (LB × LH): as needed
  • Large variety of frames and installation options

Sliding door

Sliding doors are easy to open and close – even under different pressure conditions .

Sliding doors are mainly used in the following cases:

  • When it comes to avoiding an opening into the room e.g., because there is a road behind the door
  • If a swing door is difficult to open or close against increased air pressure (event ventilation).Prerequisite is then appropriate space to the side.


A wide range is also available here

  • Opening: one or two-leaf
  • Manual, with opening aid or with drive
  • Fire resistance: none, EI30, EI60, EI90, EI120
  • Pressure load up to 5 kPa
  • Steel or stainless steel according to specification, also with powder coating
  • Dimensions (LB × LH): as needed

Swinging gates

Large-format door leaves offer opening width for vehicles

Individual large-format swinging gates allow, for example, crossover passages, technical rooms or space for larger numbers of people.

A smaller door can also be integrated in the door leaf, for example, as an escape door.

  • Opening: one or two-lief
  • Manual or with drive
  • Fire resistance: none, EI30, EI90
  • Pressure load: +/- 5 kPa
  • Dimension (LB × LH): up to 4,250 × 5,000 mm
  • Steel or stainless steel according to specification, also with powder coating

Sliding gates

Large-format door leaves offer opening width for vehicles

Individual large-format swinging gates allow, for example, crossover passages, technical rooms or space for larger numbers of people. A smaller door can also be integrated in the door leaf, for example, as an escape door.

  • Opening: one or two-leaf
  • Manual or with drive
  • Fire resistance: none, EI30, EI90
  • Pressure load: +/- 5 kPa
  • Dimension (LB × LH): up to 4,250 × 5,000 mm
  • Steel or stainless steel according to specification, also with powder coating

Folding gates

Large opening widths for accessible cross-sections with low space requirements

As a folding system, particularly large opening widths can be realised without taking up much space – neither to the front as with a hinged gate, nor to the side as with a sliding gate. The number of leaves makes large widths possible.

 

A smaller door can also be integrated in the door leaf for fast passage.

  • Opening: manual; from the side or from the middle
  • Fire resistance: none, EI30, EI90
  • Pressure load: +/- 5 kPa
  • Dimension (LB × LH): up to 6,650 × 4,250 mm
  • Steel or stainless steel according to specification, also with powder coating

Floor gates

To enable accessibility across different levels

Floor gates for closure of horizontal openings.

  • Type: one or two-leaf
  • Fire resistance: none, EI30, EI90
  • Pressure load: up to +/- 5 kPa
  • Dimensions: (LB × LH): up to 3,500 × 3,500 mm
  • Opening aids: integrated or on-site

Niche termination

If the door is supplemented with a wall to provide a room closure; for example, to have a quiet place to make an SOS call.

Niche termination with integrated swing door, for example, for SOS rooms or service niches. A version with side walls or as an independent cabin is also possible.

  • Fire resistance: none, EI30, EI60, EI90
  • Soundproofing if needed
  • Pressure load: up to 5 kPa
  • Niche geometry: as needed
  • Dimensions: door up to 2,000 × 2,500
  • Variety of installation options